ELK3190-96T, Human NPTX2(Neuronal Pentraxin II) ELISA Kit, 96T

ELK3190-96T, Human NPTX2(Neuronal Pentraxin II) ELISA Kit, 96T

ELK3192-96T, Mouse SCT(Secretin) ELISA Kit, 96T

ELK3192-96T, Mouse SCT(Secretin) ELISA Kit, 96T

ELK3192-48T, Mouse SCT(Secretin) ELISA Kit, 48T

2.142,00 RON

Mouse SCT(Secretin) ELISA Kit

SKU
ELK3192-48T

Alternative Names: Sct ; Secretin

Species: Mouse

Assay Type: Competitive Inhibition

Sensitivity: 4.83 pg/mL

Standard: 1000 pg/mL

Detection range: 15.63-1000 pg/mL

Sample type: Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids

Assay length: 2h

Research Area: Endocrinology;Hepatology;Hormone metabolism;

Test principle: This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with Mouse SCT protein. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse SCT. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse SCT in the samples is then determined by comparing the OD of the samples to the standard curve.

Mai multe informatii
Price 1.800,00 RON (preturile sunt fara TVA)
Description

Alternative Names: Sct ; Secretin

Species: Mouse

Assay Type: Competitive Inhibition

Sensitivity: 4.83 pg/mL

Standard: 1000 pg/mL

Detection range: 15.63-1000 pg/mL

Sample type: Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids

Assay length: 2h

Research Area: Endocrinology;Hepatology;Hormone metabolism;

Test principle: This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with Mouse SCT protein. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse SCT. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse SCT in the samples is then determined by comparing the OD of the samples to the standard curve.