ELK0229-96T, Rat ECE1(Endothelin Converting Enzyme 1) ELISA Kit, 96T

ELK0229-96T, Rat ECE1(Endothelin Converting Enzyme 1) ELISA Kit, 96T

ELK022ES-96T, EasyStep Rat E2(Estradiol) ELISA Kit, 96T

ELK022ES-96T, EasyStep Rat E2(Estradiol) ELISA Kit, 96T

ELK022ES-48T, EasyStep Rat E2(Estradiol) ELISA Kit, 48T

2.689,40 RON

EasyStep Rat E2(Estradiol) ELISA Kit

SKU
ELK022ES-48T

Alternative Names: 17B-Estradiol; Oestradiol; Beta-Estradiol

Species: Rat

Assay Type: Competitive Inhibition

Sensitivity: 25 pg/mL

Standard: 1600 pg/mL

Detection range: 25-1600 pg/mL

Sample type: Serum

Assay length: 1.5h

Research Area: Endocrinology;Reproductive science;Hormone metabolism;

Test principle: This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with Rat E2 antigen, and the Rat E2 standard plate wells that pre-coated using protein-related techniques are provided separately. Standard/Sample Diluent Buffer or samples are added to the appropriate microtiter plate wells ,then added a HRP-conjugated antibody specific to Rat E2 to each microplate well and incubated . After TMB substrate solution is added, the enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ±10nm. The concentration of Rat E2 in the samples is then determined by comparing the OD of the samples to the standard curve.

Mai multe informatii
Price 2.260,00 RON (preturile sunt fara TVA)
Description

Alternative Names: 17B-Estradiol; Oestradiol; Beta-Estradiol

Species: Rat

Assay Type: Competitive Inhibition

Sensitivity: 25 pg/mL

Standard: 1600 pg/mL

Detection range: 25-1600 pg/mL

Sample type: Serum

Assay length: 1.5h

Research Area: Endocrinology;Reproductive science;Hormone metabolism;

Test principle: This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with Rat E2 antigen, and the Rat E2 standard plate wells that pre-coated using protein-related techniques are provided separately. Standard/Sample Diluent Buffer or samples are added to the appropriate microtiter plate wells ,then added a HRP-conjugated antibody specific to Rat E2 to each microplate well and incubated . After TMB substrate solution is added, the enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ±10nm. The concentration of Rat E2 in the samples is then determined by comparing the OD of the samples to the standard curve.