D5032-E, EZ-96 DNA Methylation-Lightning Kit (Shallow-Well) (2x96 rxns.)  CE-IVD

D5032-E, EZ-96 DNA Methylation-Lightning Kit (Shallow-Well) (2x96 rxns.) CE-IVD

D5049-3, M-Binding Buffer (100 ml)

D5049-3, M-Binding Buffer (100 ml)

D5049, EZ DNA Methylation-Lightning Automation Kit (96 preps)

2.106,30 RON

The EZ DNA Methylation-Lightning Automation Kit is a high-throughput DNA bisulfite conversion kit designed for streamlining automation workflows. It is recommended for several downstream Illumina® Infinium® products such as MethylationEPIC, HTS iSelect® Methyl Custom, and Mouse Methylation BeadChip Arrays. This automation-specific kit features optimized buffer volumes for consistent performance on all open platform liquid handlers and magnetic bead transfer automated systems. Verified automation scripts are readily available for use on the Hamilton Microlab® STAR™/STARlet™, Thermo Fisher Scientific KingFisher™ Flex, and Tecan Fluent®.

SKU
ZR_D5049
HIGHLIGHTS

  • Automation-specific streamlined design for high-throughput bisulfite conversion of DNA for methylation analysis.
  • Compatible with Illumina® Infinium™ MethylationEPIC, HTS iSelect® Methyl Custom, and Mouse Methylation arrays.
  • Optimized buffer volumes for consistent automation performance.
DESCRIPTION

 

The EZ DNA Methylation-Lightning Automation Kit is a high-throughput DNA bisulfite conversion kit designed for streamlining automation workflows. It is recommended for several downstream Illumina® Infinium® products such as MethylationEPIC, HTS iSelect® Methyl Custom, and Mouse Methylation BeadChip Arrays. This automation-specific kit features optimized buffer volumes for consistent performance on all open platform liquid handlers and magnetic bead transfer automated systems. Verified automation scripts are readily available for use on the Hamilton Microlab® STAR™/STARlet™, Thermo Fisher Scientific KingFisher™ Flex, and Tecan Fluent®.

For automation scripts and support, email automation@zymoresearch.com.

 

TECHNICAL SPECIFICATIONS

Binding Capacity 1 µg total DNA per 5 µl MagBinding Beads
Conversion Efficiency > 99.5% of non-methylated C residues are converted to U; > 99.5% protection of methylated cytosines.
DNA Purity A260/A280 & A260/A230 ≥ 1.8
Input 100 pg - 2 µg of DNA. For optimal results, the amount of input DNA should be from 200 to 500 ng.
Input Recovery > 80% (≥ 100 bp)
Required Equipment Thermal cycler with heated lid.
Sample Source Purified genomic DNA, endonuclease-digested DNA, linearized plasmid DNA, etc. DNA should be high-quality and RNA-free.
User Provided Materials Ethanol (95 – 100%), non-skirted 96-well microplates, and 96-well microplate sealing films.

See Recommendations for instrument hardware and labware requirements.
Supplemental Info

Mai multe informatii

Mai multe informatii
Price 1.770,00 RON (preturile sunt fara TVA)
Description
HIGHLIGHTS

  • Automation-specific streamlined design for high-throughput bisulfite conversion of DNA for methylation analysis.
  • Compatible with Illumina® Infinium™ MethylationEPIC, HTS iSelect® Methyl Custom, and Mouse Methylation arrays.
  • Optimized buffer volumes for consistent automation performance.
DESCRIPTION

 

The EZ DNA Methylation-Lightning Automation Kit is a high-throughput DNA bisulfite conversion kit designed for streamlining automation workflows. It is recommended for several downstream Illumina® Infinium® products such as MethylationEPIC, HTS iSelect® Methyl Custom, and Mouse Methylation BeadChip Arrays. This automation-specific kit features optimized buffer volumes for consistent performance on all open platform liquid handlers and magnetic bead transfer automated systems. Verified automation scripts are readily available for use on the Hamilton Microlab® STAR™/STARlet™, Thermo Fisher Scientific KingFisher™ Flex, and Tecan Fluent®.

For automation scripts and support, email automation@zymoresearch.com.

 

TECHNICAL SPECIFICATIONS

Binding Capacity 1 µg total DNA per 5 µl MagBinding Beads
Conversion Efficiency > 99.5% of non-methylated C residues are converted to U; > 99.5% protection of methylated cytosines.
DNA Purity A260/A280 & A260/A230 ≥ 1.8
Input 100 pg - 2 µg of DNA. For optimal results, the amount of input DNA should be from 200 to 500 ng.
Input Recovery > 80% (≥ 100 bp)
Required Equipment Thermal cycler with heated lid.
Sample Source Purified genomic DNA, endonuclease-digested DNA, linearized plasmid DNA, etc. DNA should be high-quality and RNA-free.
User Provided Materials Ethanol (95 – 100%), non-skirted 96-well microplates, and 96-well microplate sealing films.

See Recommendations for instrument hardware and labware requirements.
Supplemental Info