The His-Spin Protein Miniprep provides a fast spin-column based purification technology for His-tagged proteins. Up to 1 mg of His-tagged protein can be purified in 5 minutes and eluted in as little as 100 µl of His-Elution Buffer. The purified protein is ultra-pure and can be used directly for enzymatic assays, protein biochemical analyses, SDS-PAGE and other sensitive applications. The straightforward spin, wash, and elute protocol dramatically simplifies protein purification and allows the end user to get results in minutes, not hours.
Fast: Purify His-tagged proteins from cell lysates in less than 5 minutes.
Simple: Prepare pure protein for small-scale studies using a spin-column.
Convenient: No special instrumentation needed other than a benchtop microcentrifuge.
DESCRIPTION
The His-Spin Protein Miniprep provides a fast spin-column based purification technology for His-tagged proteins. Up to 1 mg of His-tagged protein can be purified in 5 minutes and eluted in as little as 100 µl of His-Elution Buffer. The purified protein is ultra-pure and can be used directly for enzymatic assays, protein biochemical analyses, SDS-PAGE and other sensitive applications. The straightforward spin, wash, and elute protocol dramatically simplifies protein purification and allows the end user to get results in minutes, not hours.
TECHNICAL SPECIFICATIONS
Affinity Matrix
Nickel charged agarose
Binding Capacity
1 mg
Elution Method
Imidazole gradient
Elution Volume
100 - 200 µl (150 µl is optimal)
Principle of Technology
Based on a nickel-charged His-Affinity Gel (IMAC).
Processing Time
5 minutes
Product Storage
Please store the His-Affinity Gel, His-Binding Buffer, His-Wash Buffer, and His-Elution Buffer at 4°C. The other components can be stored at room temperature.
Protein Purity
Electrophoretically pure. Purified high-quality protein is suitable for enzyme kinetics, protein biochemical analyses, SDS-PAGE, and other applications.
Required Equipment
Microcentrifuge
Sample Type
Cell lysates or other complex protein mixtures containing His-tagged proteins.
Fast: Purify His-tagged proteins from cell lysates in less than 5 minutes.
Simple: Prepare pure protein for small-scale studies using a spin-column.
Convenient: No special instrumentation needed other than a benchtop microcentrifuge.
DESCRIPTION
The His-Spin Protein Miniprep provides a fast spin-column based purification technology for His-tagged proteins. Up to 1 mg of His-tagged protein can be purified in 5 minutes and eluted in as little as 100 µl of His-Elution Buffer. The purified protein is ultra-pure and can be used directly for enzymatic assays, protein biochemical analyses, SDS-PAGE and other sensitive applications. The straightforward spin, wash, and elute protocol dramatically simplifies protein purification and allows the end user to get results in minutes, not hours.
TECHNICAL SPECIFICATIONS
Affinity Matrix
Nickel charged agarose
Binding Capacity
1 mg
Elution Method
Imidazole gradient
Elution Volume
100 - 200 µl (150 µl is optimal)
Principle of Technology
Based on a nickel-charged His-Affinity Gel (IMAC).
Processing Time
5 minutes
Product Storage
Please store the His-Affinity Gel, His-Binding Buffer, His-Wash Buffer, and His-Elution Buffer at 4°C. The other components can be stored at room temperature.
Protein Purity
Electrophoretically pure. Purified high-quality protein is suitable for enzyme kinetics, protein biochemical analyses, SDS-PAGE, and other applications.
Required Equipment
Microcentrifuge
Sample Type
Cell lysates or other complex protein mixtures containing His-tagged proteins.