80106,  µ-Slide I ibiTreat: #1.5 polymer coverslip, tissue culture treated, sterilized,  15 Pcs/box

80106, µ-Slide I ibiTreat: #1.5 polymer coverslip, tissue culture treated, sterilized, 15 Pcs/box

80131,  µ-Dish 35 mm, low Uncoated: Ø 35 mm, low wall (800 µl volume), #1.5 polymer coverslip, hydrophobic, sterilized,  60 Pcs/box

80131, µ-Dish 35 mm, low Uncoated: Ø 35 mm, low wall (800 µl volume), #1.5 polymer coverslip, hydrophobic, sterilized, 60 Pcs/box

80126, µ-Slide y-shaped ibiTreat: #1.5 polymer coverslip, tissue culture treated, sterilized, 15 Pcs/box

1.544,62 RON

A flow through μ-Slide for bifurcation studies and blood vessel simulation

SKU
IBI_80126

A flow through μ-Slide for bifurcation studies and blood vessel simulation

  • Perfect simulation of live conditions in branching blood vessels
  • Allows flows in two different directions under different angle

 

Applications

  • Rolling and adhesion of leukocytes on endothelial cells cultured under flow
  • Simulation of the bifurcation of blood vessels for arteriosclerosis research
  • Cell-cell interaction studies and cell-drug interaction screenings under flow conditions

Technical Features

  • 30° and 45° angles to simulate the bifurcation of blood vessels
  • Easy connection to tubes and pumps
  • Fully compatible with high resolution microscopy and immunofluorescence staining
  • Defined shear stress and shear rate levels
  • The flow is always laminar, i.e., turbulent flows* are not possible

Specifications

Outer dimensions (w x l)

25.5 x 75.5 mm²

Adapters

Female Luer

Volume per reservoir

60 µl

Volume of the channel

110 µl

Height of the channel

0.4 mm

Width of the channel

3 mm

Branching angles

30° and 45°

Growth area

2.8 cm2

Coating area using 110 µl

5.6 cm2

Bottom: ibidi Polymer Coverslip

 

Mai multe informatii
Price 1.298,00 RON (preturile sunt fara TVA)
Description

A flow through μ-Slide for bifurcation studies and blood vessel simulation

  • Perfect simulation of live conditions in branching blood vessels
  • Allows flows in two different directions under different angle

 

Applications

  • Rolling and adhesion of leukocytes on endothelial cells cultured under flow
  • Simulation of the bifurcation of blood vessels for arteriosclerosis research
  • Cell-cell interaction studies and cell-drug interaction screenings under flow conditions

Technical Features

  • 30° and 45° angles to simulate the bifurcation of blood vessels
  • Easy connection to tubes and pumps
  • Fully compatible with high resolution microscopy and immunofluorescence staining
  • Defined shear stress and shear rate levels
  • The flow is always laminar, i.e., turbulent flows* are not possible

Specifications

Outer dimensions (w x l)

25.5 x 75.5 mm²

Adapters

Female Luer

Volume per reservoir

60 µl

Volume of the channel

110 µl

Height of the channel

0.4 mm

Width of the channel

3 mm

Branching angles

30° and 45°

Growth area

2.8 cm2

Coating area using 110 µl

5.6 cm2

Bottom: ibidi Polymer Coverslip