B00000, RAA Nucleic Acid Amplification Kit, for end-point amplicon detection using gel electrophoresis (48 reactions)

B00000, RAA Nucleic Acid Amplification Kit, for end-point amplicon detection using gel electrophoresis (48 reactions)

T00R01, RAA Nucleic Acid Amplification Kit, for lateral flow-strip detection (48 reactions)

T00R01, RAA Nucleic Acid Amplification Kit, for lateral flow-strip detection (48 reactions)

F00R01, RAA Nucleic Acid Amplification Kit, for fluorescent probe-based real-time detection (48 reactions)

1.840,93 RON

(RT-)RAA Nucleic Acid Amplification Kit (Fluorescent Method) can be used to amplify nucleic acids. The amplification result can be verified by use of fluorescent probes in real-time.

SKU
XD_F00R01

(RT-)RAA Nucleic Acid Amplification Kit (Fluorescent Method) can be used to amplify nucleic acids. The amplification result can be verified by use of fluorescent probes in real-time.

ADVANTAGES

Rapid amplification and real-time detection

RAA technology amplifies RNA and DNA in just a few minutes. Positive amplification results are usually detectable after 3 to 10 minutes incubation, provided an appropriate fluorescence reader is used for incubation. 

Aliquoted freeze-dried reagent mixes

Recombinase Aided Amplification kits are convient to handle. They comprise of freeze-dried enzyme mix aliquoted in standard 0.2mL PCR tubes and of two buffers for rehydration and starting the amplification reaction.

Reverse transcriptase included

In the RT-version of RAA kits, the reverse transcriptase enzyme is included in the freeze-dried reagent pellet. There is no extra pipetting step and no extra costs.

 

Mai multe informatii

Mai multe informatii
Price 1.547,00 RON (preturile sunt fara TVA)
Description

(RT-)RAA Nucleic Acid Amplification Kit (Fluorescent Method) can be used to amplify nucleic acids. The amplification result can be verified by use of fluorescent probes in real-time.

ADVANTAGES

Rapid amplification and real-time detection

RAA technology amplifies RNA and DNA in just a few minutes. Positive amplification results are usually detectable after 3 to 10 minutes incubation, provided an appropriate fluorescence reader is used for incubation. 

Aliquoted freeze-dried reagent mixes

Recombinase Aided Amplification kits are convient to handle. They comprise of freeze-dried enzyme mix aliquoted in standard 0.2mL PCR tubes and of two buffers for rehydration and starting the amplification reaction.

Reverse transcriptase included

In the RT-version of RAA kits, the reverse transcriptase enzyme is included in the freeze-dried reagent pellet. There is no extra pipetting step and no extra costs.