The store will not work correctly in the case when cookies are disabled.
80046, Adapter for sticky-Slide 8 Well high
80126-120, µ-Slide y-shaped ibiTreat, Bulk Pack 120: #1.5 polymer coverslip, tissue culture-treated, sterilized, 8 per tray, 15 trays
80126-90, µ-Slide y-shaped ibiTreat, Bulk Pack 90: #1.5 polymer coverslip, tissue culture-treated, sterilized, individually packed
A flow through μ-Slide for bifurcation studies and blood vessel simulation
A flow through μ-Slide for bifurcation studies and blood vessel simulation
- Perfect simulation of live conditions in branching blood vessels
- Allows flows in two different directions under different angle
Applications
- Rolling and adhesion of leukocytes on endothelial cells cultured under flow
- Simulation of the bifurcation of blood vessels for arteriosclerosis research
- Cell-cell interaction studies and cell-drug interaction screenings under flow conditions
Technical Features
- 30° and 45° angles to simulate the bifurcation of blood vessels
- Easy connection to tubes and pumps
- Fully compatible with high resolution microscopy and immunofluorescence staining
- Defined shear stress and shear rate levels
- The flow is always laminar, i.e., turbulent flows* are not possible
Specifications
Outer dimensions (w x l)
|
25.5 x 75.5 mm²
|
Adapters
|
Female Luer
|
Volume per reservoir
|
60 µl
|
Volume of the channel
|
110 µl
|
Height of the channel
|
0.4 mm
|
Width of the channel
|
3 mm
|
Branching angles
|
30° and 45°
|
Growth area
|
2.8 cm2
|
Coating area using 110 µl
|
5.6 cm2
|
Bottom: ibidi Polymer Coverslip
|
Mai multe informatii
Mai multe informatii
Price |
6.622,00 RON (preturile sunt fara TVA) |
Description |
A flow through μ-Slide for bifurcation studies and blood vessel simulation
- Perfect simulation of live conditions in branching blood vessels
- Allows flows in two different directions under different angle
Applications
- Rolling and adhesion of leukocytes on endothelial cells cultured under flow
- Simulation of the bifurcation of blood vessels for arteriosclerosis research
- Cell-cell interaction studies and cell-drug interaction screenings under flow conditions
Technical Features
- 30° and 45° angles to simulate the bifurcation of blood vessels
- Easy connection to tubes and pumps
- Fully compatible with high resolution microscopy and immunofluorescence staining
- Defined shear stress and shear rate levels
- The flow is always laminar, i.e., turbulent flows* are not possible
Specifications
Outer dimensions (w x l)
|
25.5 x 75.5 mm²
|
Adapters
|
Female Luer
|
Volume per reservoir
|
60 µl
|
Volume of the channel
|
110 µl
|
Height of the channel
|
0.4 mm
|
Width of the channel
|
3 mm
|
Branching angles
|
30° and 45°
|
Growth area
|
2.8 cm2
|
Coating area using 110 µl
|
5.6 cm2
|
Bottom: ibidi Polymer Coverslip
|
|